Products
- Adhesives & Sealants[7]
- Circuit Breakers[10]
- Connectors[5]
- Terminals[1]
- Electronic & Instrument Enclosures[10]
- Fuse Components[3]
- Fuses[8]
- Other Electrical Equipment[4]
- Power Accessories[10]
- Power Distribution Equipment[10]
- Relays[1]
- Other Switches[1]
- Transformers[10]
- Control Cables[1]
- Electrical Wires[1]
- Other Wires[5]
- Power Cables[2]
- Wiring Harness[1]
- Other Wiring Accessories[5]
- Electrical Ceramics[2]
- Insulation Materials & Elements[10]
- Resistors[9]
- Other Woodworking Machinery[10]
- Instrument Parts & Accessories[1]
- Pressure Regulators[1]
- Aluminum Wire[1]
- Steel Sheets[3]
- Copper Wire Mesh[1]
- Silicone Rubber[1]
Contact Us
- Contact Person : Mr. Han Daniel
- Company Name : Ru-Lena Ind. (Holding) Co., Ltd.
- Tel : 86-0411-39852517
- Fax : 86-0411-39852510
- Address : Liaoning,Dalian,1302-1305 Tower B, The Manhattan Tower, No. 101 Youhao Road, Zhongshan Dist.
- Country/Region : China
- Zip : 116001
Products List
LW34-40.5 Series Outdoor High Voltage SF6 Circuit Breaker
designed for control and protection of the electric power distribution and transimission system with voltage up to 40.5kV.
1.General DescriptionLW34-40.5 series outdoor high voltage SF6 circuit breaker is 3-phase DC 50 Hz outdoor high voltage equipment. Is designed for control...
Cable Joints 630A,36KV Deadbreak Straight Connector
1. insulated plug-in termination
2. rated 630 A,36kV
3. cable joints
4. wiht KEMA report
cable joints /cable accessories The RU YJZNP-36/630 Deadbreak Straight connector is a fully-shielded and insulated plug-in termination, rated 630 amps,36kV, connected with...
33KV Fuse Cut Out
Standards Applied: IEC 60282-2 ANSI/IEEE C37.40 ANSI/IEEE C37.41 ANSI/IEEE C37.42 KEMA Type Test Certificate for all products
Type codeYKFC02-33Rated 33voltage, kVRated100,200current,ARated breaking8/12.capacity,kALighting impulse170withstand voltage, kVPower...
3KV5KA ZnO Varistor
The S.A. assembled by our ZnO blocks have passed KEMA type test. Provide routine test before shipment to guarantee the quality!
Description3kv5kA Rated voltage,kV3MCOV,kV2.55Lightning impulse(8/20)residual voltage, kV 5KA9.010KA10.320KA11Switch impulse(30/60)...
All Aluminium Stranded Conductor
As domestic users are accustomed to purchasing AAC or ACSR according to GB1179-83, the type,structure and performance of this pr
One Product Standard As domestic users are accustomed to purchasing AAC or ACSR according to GB1179-83, the type,structure and performance of this...
SMC meter box
1. SMC meter box
2. electrical & thermal insulation, flame retardation & low-smoke, aging resistance
3. customer-oriented
SMC meter box/fiberglass enclosure It can be directly fixed on the wall or installed on the electric pole, DD282 etc. have the function of meter...
RTV Insulator Coating
This coating is widely used by power industries to coat insulator to prevent flash over,arcing under highly pulluted environment
RTV's Silicone Coating For High Voltage InsulatorsOutward appearanceDoes not have the obvious mechanical impurity and the cotton wool...
cable feeder
Uses:to string large diameter electric power cable and communication cable.
Cable FeederOrder numberDiameter of suitable cable (mm)Linepull(KN)line speed(m/min)ratingMotor power(KW)Dimension(mm)Weight(kg)Remark21101φ60-φ1203/6.50.75950×500×550165Updown...
33KV Cut Out Fuse
Standards Applied: IEC 60282-2 ANSI/IEEE C37.40 ANSI/IEEE C37.41 ANSI/IEEE C37.42 KEMA Type Test Certificate for all products
Type codeYKFC02-33Rated 33voltage, kVRated100,200current,ARated breaking8/12.capacity,kALighting impulse170withstand voltage, kVPower...
Pressure Release Valve for transformer
used for transofrmer and be capable to be remoted control
Pressure Release Valve for transformer
...